6. USING THE OPERATION PANEL

6-4. Using the TEST switch (Checking the sewing pattern)

Use the TEST switch to begin sewing again from any desired point when the thread breaks or the bobbin thread runs out.

1217S

 

1215S

1. Press the TEST switch (15). The indicator (16) will

 

light.

 

 

 

 

 

 

 

 

 

 

2. If the work clamp is raised, depress the work clamp

 

 

 

 

 

lifter pedal (2) to lower the work clamp.

 

 

 

 

 

3. Press the starting pedal (1).

 

(16)

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

 

 

 

After the feed mechanism has returned to the

 

 

 

 

 

home position, it will then move the sewing start

 

 

 

 

 

position and the program number will stop

 

 

 

 

 

flashing.

 

 

 

 

 

This only occurs the first time that a program is

(15)

(17)

 

selected.

 

 

 

 

 

4. Press the starting pedal (1). (The needle will remain

 

 

 

 

 

stationary as the work clamp advances through the

 

 

 

 

 

pattern at low speed one stitch at a time. Press the

 

 

 

 

 

presser lifter pedal (2) to fast forward.

 

 

 

 

 

If the STEP BACK switch (17) is pressed while moving

 

 

 

 

 

at low speed when memory switch No. 20 is ON, the

 

 

 

 

 

work clamp will move in the forward direction in steps

 

 

 

 

 

of 100 stitches.

 

 

 

 

 

5. When the work clamp reaches the desired position,

 

 

 

 

 

press the TEST switch (15). The work clamp will stop,

 

 

 

 

 

and the test indicator (16) will go out. If the work clamp

 

 

 

 

 

was stopped too early, press theTEST switch (15)

 

 

 

 

 

again to proceed.

 

 

 

 

 

If the work clamp was stopped too late, press the

(2)

(1)

 

STEP BACK switch (17) to advance the work clamp

 

one stitch at a time.

 

 

 

 

 

 

 

 

1218S

Resuming operation from a stopping poing

 

 

 

 

 

6. Sewing will start when the starting pedal (1) is

 

 

 

 

 

pressed.

BAS-311F-0, 311F-L, 326F-0

31

Page 38
Image 38
Brother BAS-311F-0, BAS-326F-0 Using the Test switch Checking the sewing pattern, Resuming operation from a stopping poing