12. ERROR CODES

Code

Cause

 

 

 

Remedy

 

 

 

 

 

 

 

E.40

Floppy disk is not inserted or operation panel cable

Insert a floppy disk. If floppy disk is already inserted,

 

is not securely connected.

turn off the power and check the connections of cords

 

 

inside the operation panel.

 

 

 

 

E.41

Invalid program No., or no data.

Change program No..

 

 

 

 

 

E.43

Different floppy disk!

Use original floppy disk.

 

 

 

 

 

 

 

 

E.4F

Error occurred during floppy disk data reading.

Replace the floppy disk and repeat the operation.

 

 

 

 

 

 

 

E.50

Floppy disk is write-protected.

Release write-protection.

 

 

 

 

E.51

Insufficient available memory on floppy disk.

Use another floppy disk.

 

 

 

 

E.52

Can not format this floppy disk.

Change floppy disk.

 

 

 

 

 

E.5F

Error occurred during data writing on floppy disk.

Replace the floppy disk and repeat the operation.

 

 

 

E.60

Can not backup data. (Panel PCB)

Turn off power and then clear all of the memory setting.

E.61

Can not backup data. (Control PCB)

Turn off power and then clear all of the memory setting.

E.62

Operation panel error.

Turn off power and then on again.

 

 

 

E.63

Combination of control PROM and operation panel

Turn off power and check it

 

 

 

 

 

PROM is invalid.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E.70

Same optional output number already exists.

Change optional output number.

 

 

 

 

 

 

If not use optional output, turn off power and then clear

 

 

all of the memory setting.

 

 

 

 

E.71

Bobbin changer error!

See the manual for bobbin changer.

 

 

 

-

 

If not using the bobbin changer, set memory switch 23

E.74

 

to OFF.

 

 

 

 

 

 

 

E.75

Milling motor has stopped due to overload.

See the manual for Milling motor.

 

 

 

 

 

If not use milling motor, set OFF memory switch 10.

 

 

 

 

 

 

 

 

 

 

E.80

Upper thread has broken. (Rotary type sensor)

Thread

upper

thread

again.

You

can

start

sewing

 

 

again.

 

 

 

 

 

 

 

E.81

Upper thread has broken. (Optical fiber type sensor)

Thread

upper

thread

again.

You

can

start

sewing

 

 

again.

 

 

 

 

 

 

 

 

 

 

 

 

 

E.90

Power supply voltage is extremely low.

Turn off power and check voltage.

 

 

 

E.91

Power supply voltage is extremely high.

Turn off power and check voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

64

BAS-311F-0, 311F-L, 326F-0

Page 71
Image 71
Brother BAS-311F-0, BAS-326F-0, BAS-311F-L instruction manual Can not backup data. Control PCB