Installing Optional Fast Ethernet Interface Modules

When installing Fast Ethernet Interface Modules in both port

TIP slots 7 and 8, remove the coverplates from both slot openings. In the following instructions, the optional module is shown being installed in port slot 8.

1.Remove the coverplate from the port slot where the Fast Ethernet Interface Module will be installed. Refer to Figure C-4and proceed as follows:

a.Remove the two screws fastening the coverplate to the standoffs. Save the screws.

b.Lift and remove the coverplate from the top of the front standoffs.

Coverplate

Rear

Standoff

Front

Standoffs

2251-38

Figure C-4 Coverplate Removal

2.Remove the screw from the rear standoff. Save the screw.

NOTE

When installing an FE-100FX or FE-100F3 module into the 2H28-08R, remove the rubber plug on the module before proceeding.

2H28-08R SmartSwitch 2208 User’s Guide

C-7

Page 145
Image 145