Broadcast Suppression Screen
Threshold (Modifiable)
Allows the user to set the desired limit of receive broadcast frames that will be forwarded per port per second.
Reset Peak (Toggle)
Allows the user to reset the Peak Rate counter. Resetting the Peak Rate also resets the Time Since Peak field. The Reset Peak field default position is NO.
5.16.1 Setting the Threshold
To set the Threshold, proceed as follows:
1.Use the arrow keys to highlight the Threshold field for the selected port.
2.Type in the numbers for the desired limit. Only enter values in increments of ten (for example; 10, 20, 30, etc.).
3.Use the arrow keys to highlight the SAVE command at the bottom of the screen.
4.Press ENTER. The message “SAVED OK” displays.
5.16.2 Setting the Reset Peak Switch
To use the Reset Peak field to clear the Peak Rate counter, proceed as follows:
1.Use the arrow keys to highlight the Reset Peak field for the selected port.
2.Press the SPACE bar to select YES.
3.Use the arrows keys to highlight the SAVE command at the bottom of the screen.
4.Press ENTER. The message “SAVED OK” displays and the Time Since Peak field is also reset.
|