Appendix C: Optional Installations and Mode Switch Bank Settings
C.2.1 Setting the Mode Switch
Figure C-2 shows the location of the mode switches and the switch settings for normal operation. These switches are set at the factory and do not need to be changed.
TOP VIEW WITHOUT COVER
Flash
Primary
Power
Supply
Redundant
Power
Supply
MODE SWITCH BANK
8 7 6 5 4 3 2 1
OFF
ON
DRAM
FRONT PANEL |
Figure C-2 2H28-08R Mode Switch Location/Component Layout
Switch definitions and positions are as follows:
•Switches 1 through 4 – For Cabletron Systems use only.
•Switch 5 – COM Port Autobaud. The default (OFF) position enables Autobaud sensing on the COM port for Local Management sessions. Changing the switch to the ON position disables Autobaud sensing and sets the COM port to 9600 baud for Local Management sessions.
|