General Configuration Screen
5.When the message “SAVED OK” appears, the edits are saved.
NOTE |
Exiting without saving causes the message “NOT SAVED
5.7.10.1 Changing the COM Port Application
After enabling the COM port as described in Section 5.7.10, you can select one of the applications supported by the COM port: LM or UPS. The default application is LM.
To change the COM port application:
1.Use the arrows keys to highlight the Application field.
2.Use the SPACE bar or BACKSPACE to toggle the available settings until the operation you require appears. Table
| Table | |
|
|
|
Setting |
| Application |
|
|
|
|
|
|
LM |
| Local Management Session |
|
|
|
UPS |
| APC Power Supply SNMP Proxy |
|
|
|
3.Press ENTER to accept the application.
4.Use the arrow keys to highlight the SAVE command at the bottom of the screen, then press the ENTER key.
5.When the message “SAVED OK” displays, the edits are saved.
When the COM port is configured to perform the UPS
!application, all future Local Management connections must be
CAUTION | made by establishing a Telnet connection to the device. Ensure |
| |
| that the device has a valid IP address before saving changes to |
| the COM port application. If the module does not have a valid |
| IP address and the changes are saved, refer to Appendix C for |
| instructions on clearing NVRAM in order to reestablish COM |
| port communications. |
|