Cabletron Systems 3Com manual Troubleshooting, Verify AP Operation

Models: 3Com

1 93
Download 93 pages 14.35 Kb
Page 34
Image 34
Troubleshooting

34CHAPTER 2: INSTALLING ACCESS POINT HARDWARE

Troubleshooting

Check the following symptoms and their possible causes before contacting the

 

3Com Support Center.

Verify AP Operation

1If the AP does not power up, you may be experiencing one of the following:

Faulty AP power supply

Failed AC supply

Electrical Management System (EMS) operating outlet

2After the AP resets and hardware is initialized, it performs an SRAM test. If the test passes, all three LEDs turn on. If the test fails, the LEDs all turn off and the AP resets. The LEDs turn off sequentially, in the order shown, as each of the following tests pass.

 

LED

State

Test Passed

 

 

 

 

 

 

 

 

 

Power

Blinks

Bootup and run-time codes

 

 

 

 

 

 

continuously

downloaded to AP flash memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

successful. Run-time code controls the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AP.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wireless LAN Activity

Off

Serial port initialized, FIFO buffer

 

 

 

 

 

 

 

flushed, serial port to AP connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

checked.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wired LAN Activity

Off

LAN adapter present.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Identify wired network problems:

3No operation:

Verify AP configuration via Telnet, PPP or UI. Review procedures for Ethernet and serial connection of the AP. Review AP firmware revisions and update procedures.

Verify network configuration by ensuring that there are no duplicate IP addresses. Power down the device in question and ping the assigned address of the device. Ensure no other device responds to that address.

4AP powered on but has no connection to the wired network:

Check connections for proper wiring.