Using the TRMMIM Hub View

-INS (Inserted) indicates the port has been enabled by management, and there is a station linked to the port.

-ACT indicates a ring port is active and passing data.

-WRAP indicates data communications have been terminated at the ring port, and it has wrapped so that the ring’s back-up path is in effect.

-“---” for ring ports without a connection, or for any port with an unknown connection status.

Admin Status displays either ON or OFF, an indication of whether management has the port enabled or disabled. A port can be ON but not operational. Under the Admin display, ports that are enabled but not linked are shown as ON.

Media Type applies only to selectable-media ring ports and indicates the type of cabling supported by the port:

-On a module with media-selectable ring ports, the ring ports will display the current selection: FO (Fiber Optic) or STP (Shielded Twisted Pair).

-On a module without selectable ring ports, the ring ports will display “UNS”.

-Ring ports that do not have media selection will display “---”.

-Station ports will display “---”.

Active Ports displays the following information about statistics for the port:

-Yes if a linked (green with INS Admin/Link status) port on the TRMMIM-managed ring has recorded statistics since the statistical counters were last reset.

-No if a linked (green with INS Admin/Link status) port on the TRMMIM-managed ring has not recorded statistics since the statistical counters were last reset.

-“---”for non-TRMMIM-managed ports (i.e., ports that are not on the managed ring), regardless of their status.

FNB Display

NOTE

The FNB Display option is meant for use with multi-Token Ring management modules (e.g., the TRMM-2 and TRMM-4) and port switching MIMs (e.g., the TRXMIM and TDRMIM) in order to view the FNB connection status of the port switching MIMs.

Since the TRMMIM is a single-Token Ring management module, only the FNB 1 display selection (which is the default display for your Hub View) is applicable.

2-10

Using the Hub View

Page 26
Image 26
Cabletron Systems TRMMIM manual FNB Display