Ring Map

Code

Error

 

 

 

 

0

No problem detected

 

 

32

Ring Recovery Error

The management station has observed claim token MAC frames on the ring.

 

 

 

64

Single Station

The management station has sensed it is the only station on the ring.

 

 

 

128

Counter Overflow

One of the management station’s error counters has incremented from 254 to 255.

 

 

 

 

Remove Received

256

The management station has received a remove ring station MAC frame request

 

and has removed itself from the ring.

 

 

 

Auto-Removal Error

1024

The management station has failed the lobe wrap test resulting from the beacon

 

auto-removal process and has removed itself from the ring.

 

 

 

Lobe Wire Fault

2048

The management station has detected an open or short circuit in the cable between

 

itself and the wiring concentrator or hub.

 

 

4096

Transmit Beacon

The management station is transmitting beacon frames to the ring.

 

 

 

8192

Soft Error

The management station has transmitted a report error MAC frame.

 

 

 

 

Hard Error

16384

The management station is presently transmitting beacon frames to or receiving

 

beacon frames from the ring.

 

 

32768

Signal Loss

The management station has detected a loss of signal on the ring.

 

 

 

131072

No Status, Open Not Completed

 

 

Table 3-1. Error Status Codes and Definitions

Active Monitor

This field allows you to determine whether or not the management station will participate in active monitor contention. The contention process occurs as part of the recovery procedures initiated after certain ring error situations, and is used to select a new Active Monitor for the ring. If you disallow contention for the selected management station, that station will not participate in the contention process, and will therefore never be chosen as Active Monitor.

3-12

Viewing Station-specific Information

Page 62
Image 62
Cabletron Systems TRMMIM manual Error, Active Monitor