Ring Map

Figure 3-6. The Management Station Configuration Window

The Management Station Configuration window contains the following information and configurable options:

Commands

You can choose one of five commands to execute on the management station. To select a command, click mouse button 1 on the button next to it.

No-op

No operation (command) will be performed on the

 

device.

SW Reset

The device will be reset through the software; note that

 

this does not reset statistical counters.

HW Reset

A hardware reset will occur on the device, which is the

 

equivalent of physically resetting the device. This

 

reinitializes the module and all counters are reset.

Open

Forces the management station to “open” on to the ring.

 

This causes the station to participate in the ring poll

 

process and receive and transmit data onto the ring.

Close

Forces the management station to “close,” therefore

 

removing itself from the ring and making the station

 

incapable of receiving or transmitting any data onto the

 

ring.

3-10

Viewing Station-specific Information

Page 60
Image 60
Cabletron Systems TRMMIM manual Commands