BM
(ECM)
SW1 |
|
SW2 |
|
SW3 |
|
SW4 |
|
SW5 |
|
SW6 |
|
SW7 |
|
SW8 |
|
SW9 |
|
OFF | ON |
ECM
INTERFACE
BOARD
15
LEGEND
AL | — Alarm Relay Contacts | P1 | — Field Wiring Terminal Block | |||||||||
ASTAT | — Aquastat | RVS | — Reversing Valve Solenoid | |||||||||
BM | — Blower Motor | TRANS | — Transformer | |||||||||
CAP | — Capacitor |
|
|
|
|
|
|
|
|
|
| Field Line Voltage Wiring |
CB | — Circuit Breaker |
|
|
|
|
|
|
|
|
|
| Field Low Voltage Wiring |
CC | — Compressor Contactor |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Printed Circuit Trace | ||
CO | — Sensor, Condensate Overflow |
|
|
|
|
|
|
|
|
|
| |
COMPR | — Compressor |
|
|
|
|
|
|
|
|
|
| Relay/Contactor Coil |
DDC | — Direct Digital Control |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
DTS | — Discharge Temp Switch |
|
|
|
|
|
|
|
|
|
|
|
ECM | — Electronically Commutated Motor |
|
|
|
|
|
|
|
|
|
| Condensate Pan |
|
|
|
|
|
|
|
|
|
| |||
FP1 | — Sensor, Water Coil Freeze Protection |
|
|
|
|
|
|
|
|
|
| Solenoid Coil |
FP2 | — Sensor, Air Coil Freeze Protection |
|
|
|
|
|
|
|
|
|
| |
HP | — |
|
|
|
|
|
|
|
|
|
| Thermistor |
HWG | — Hot Water Generator |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
JW1 | — Jumper, Alarm |
|
|
|
|
|
|
|
|
|
| Ground |
NSB | — Digital Night Setback |
|
|
|
|
|
|
|
|
|
| Wire Nut |
LOC | — Loss of Charge Pressure Switch |
|
|
|
|
|
|
|
|
|
| |
MV | — Motorized Valve |
|
|
|
|
|
|
|
|
|
|
|
NEC | — National Electrical Code |
|
|
|
|
|
|
|
|
|
|
|
BM (ECM) |
|
| J1 |
|
| Y |
W | R | S1 |
| CFM | |
|
| SW1 |
O |
|
|
|
|
| SW2 |
| |
G |
|
|
|
| SW3 |
| ||
|
|
|
|
|
| SW4 |
| |
|
|
|
|
|
| SW5 |
| |
Y2 | G |
|
|
|
| SW6 |
| |
|
|
|
| SW7 |
| |||
|
|
|
|
|
|
| ||
|
|
|
|
|
| SW8 |
| |
Y1 | G |
|
|
|
| SW9 |
| |
|
|
|
|
| OFF | ON | ||
|
|
|
|
|
|
| ||
G | G | TB1 |
|
|
| G | DEHUM | |
|
|
|
|
|
|
|
| |
R | C | Y2 Y1 G | O | W | C | R DH AL1 A | A | AL1 |
ECM INTERFACE BOARD LAYOUT
NOTES:
1.Compressor and blower motor thermally protected internally.
2.All wiring to the unit must comply with NEC and local codes.
3.Transformer for 208/230 v will be connected for 208 v operation. For 230 v operation, discon- nect RED lead at L1 and attach ORN lead to L1. Insulate open end of RED lead. Transformer for 220/240 v will be connected for 220 v operation. For 240 v operation, disconnect RED lead at L1 and attach ORN lead to L1. Transformer is energy limiting or may have circuit breaker.
4.FP1 thermistor provides freeze protection for water. When using antifreeze solutions, cut JW3 jumper.
5.Typical Aquazone™ thermostat wiring shown. Refer to thermostat installation instructions for wiring to the unit. Thermostat wiring must be Class 1 and voltage rating equal to or greater than unit supply voltage.
6.
7.Transformer secondary ground via Deluxe D board standoffs and screws to control box. (Ground available from top two standoffs as shown.)
8.Aquastat is
9.Place jumpers on 2 and 3, ECM board, when dehumidification mode is used.