Using Drawbar Organ Tones

Adjusting a Drawbar Organ Tone in Real Time

Use the sliders and buttons to adjust drawbar organ tones in real time.

To do this:

 

Do this:

Adjust tone harmonic

Shift sliders D-4 (16') through D-12

overtone levels

(1') upwards and downwards.

 

Shifting one of the sliders

 

 

upwards or downwards changes

 

 

the harmonic overtone of the

 

 

corresponding foot “length” from

 

 

its current level (the level preset

 

 

for the tone).*1

 

You also can configure the level

 

 

meter so it indicates the harmonic

 

 

overtone level of each slider

 

 

position. For more information,

 

 

see “To configure the level meter

 

 

to show the harmonic overtone

 

 

level of each slider position”

 

 

(page E-51).

 

 

Add or remove

Use the D-2 (PERCUSSION

percussion sound with

SECOND) and D-3 (PERCUSSION

2nd overtone and 3rd

THIRD) buttons.

overtone pitch to a

Each press toggles the button

tone

 

between lit and unlit.

 

• The corresponding overtone

 

 

percussion is being applied to

 

 

notes while a button is lit, and not

 

 

being applied while it is unlit.

 

 

Switch the rotary

Press the D-1 (ROTARY SLOW/

effect speed (rotation

FAST) button.

speed)*2

Each press toggles the button

 

 

between lit and unlit.

 

Rotary speed is fast while the

 

 

button is lit and slow when it is

 

 

unlit.

 

 

 

*1 Adjustment to one of four levels, from 0 to 3, is supported. Each level is indicated by the level meter as shown below.

*2 This operation is supported only when DSP is being used as the effect and the DSP type is “Rotary”. For details about effects, see “Applying Effects to a Sound” (page E-29). For details about DSP types, see “DSP Effect List” (page E-155).

To configure the level meter to show the harmonic overtone level of each slider position

1.Perform steps 1 through 3 of the procedure under “To select and play with a drawbar organ tone” (page E-50).

The level meter shows the harmonic overtone levels for the foot “lengths” preset for the currently selected drawbar organ tone.

You also could skip this step and start from step 2 of this procedure, if you want.

2.Hold down the R-12 (MANUAL) button until the foot “length” values (16' through 1') along the top of the level meter flash twice. You can release the button at this time.

This will cause the level meter to indicate the current positions of sliders D-4 (16') through D-12 (1'), and apply applicable harmonic overtone levels to the current tone.

3.Shift sliders D-4 (16') through D-12 (1') upwards and downwards.

When you do, the displayed harmonic overtone levels will change accordingly in the level meter.

4.Now you can play on the keyboard using the level-adjusted tone.