Understanding TDR, page 47-15
Running TDR and Displaying the Results, page 47-16

Understanding TDR

You can use the Time Domain Reflector (TDR) feature to diagnose and resolve cabling problems. When
running TDR, a local device sends a signal through a cable and compare s the reflecte d signal to the initi al
signal.
TDR is supported only on 10/100/1000 copper Ethernet ports. It is not suppor ted on 10-Gigabit Ethernet
ports and on SFP module ports.
TDR can detect these cabling problems:
Open, broken, or cut twisted-pair wires—The wires are not connected to the wires from the remote
device.
Shorted twisted-pair wires—The wires are touching each other or the wires from the rem ote device.
For example, a shorted twisted pair can occur if one wire of the twisted pair is soldered to the other
wire.
If one of the twisted-pair wires is open, TDR can find the length at which the wire is open.
Use TDR to diagnose and resolve cabling problems in these situations:
Replacing a switch
Setting up a wiring closet
Troubleshooting a connection between two devices when a link cannot be established or when it is
not operating properly
When you run TDR, the switch reports accurate information if
The cable for the Gigabit link is a solid-core cable.
A Administratively unreachable. Usually, this output means that an access list is
blocking traffic.
H Host unreachable.
N Network unreachable.
P Protocol unreachable.
Q Source quench.
U Port unreachable.
Table47-2 Traceroute Output Display Characters (continued)
Character Description