48-5
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter48 Configuring Online D iagnostics Running Online Diagnostic Tests
To configure the switch to not generate a syslog message when the health-monitoring test fails, use
the no diagnostic monitor syslog global configuration command.
To return to the default failure threshold, use the no diagnostic monitor threshold switch number
test {name | test-id | test-id-range | all} failure count count global configuration command.
This example shows how to configure a health-monitoring test:
Switch(config)# diagnostic monitor threshold switch 3 test 1 failure count 50
Switch(config)# diagnostic monitor interval switch 3 test TestPortAsicRingLoopback
Running Online Diagnostic Tests
After you configure online diagnostics, you can manually start diagnostic tests or display the test results.
You can also see which tests are configured for the switch or switch stack and the diagnostic tests that
have already run.
These sections describe how to run online diagnostic tests:
Starting Online Diagnostic Tests, page 48-5
Displaying Online Diagnostic Tests and Test Results, page48-6

Starting Online Diagnostic Tests

After you configure diagnostic tests to run on the switch, u se the diagno sti c st art privileged EXEC
command to begin diagnostic testing.
Use this privileged EXEC command to manually start online diagnostic testing:
After starting the tests, you cannot stop the testing process.
Command Purpose
diagnostic start switch number
test {name | test-id | test-id-range
| all | basic | non-disruptive}
Start the diagnostic tests.
The switch number keyword is supported only on stacking-capable switches. The range
is from 1 to 9.
You can specify the tests by using one of these options:
name—Enter the name of the test. Use the show diagnostic content privileged EXEC
command to display the test ID list.
test-id—Enter the ID number of the test. Use the show diagnostic content privileged
EXEC command to display the test ID list.
test-id-range—Enter the range of test IDs by using integers separated by a comma
and a hyphen. For more information, see the diagnostic start command in the
command reference for this release.
all—Use this keyword when you want to run all of the tests.
basic—Use this keyword when you want to run the basic test suite.
non-disruptive—Use this keyword when you want to run the non-disruptive test
suite.