28-3
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter28 Configuring UDLD Configuring UDLD
If the detection window ends and no valid reply message is received, the link might shut down,
depending on the UDLD mode. When UDLD is in norm al mo de, t h e lin k mi ght be consi d er ed
undetermined and might not be shut down. When UDLD is in aggre ssive mode, the link i s
considered unidirectional, and the port is disabled.
If UDLD in normal mode is in the advertisement o r in t he d ete cti on ph as e an d a l l th e n ei ghbor c a che
entries are aged out, UDLD restarts the link-up sequence to resynchronize with any potentially
out-of-sync neighbors.
If you enable aggressive mode when all the neighbors of a port have aged out either in the advertisement
or in the detection phase, UDLD restarts the link-up sequence to resynchronize with any potentially
out-of-sync neighbor. UDLD shuts down the port if, after the fast train of messages, the link state is still
undetermined.
Figure 28-1 shows an example of a unidirectional link condition.
Figure28-1 UDLD Detection of a Unidirectional Link
Configuring UDLD
These sections contain this configuration information:
Default UDLD Configuration, page 28-4
Configuration Guidelines, page 28-4
Enabling UDLD Globally, page28-5
Enabling UDLD on an Interface, page28-6
Resetting an Interface Disabled by UDLD, page 28-6
TX
TX
RX
RX
Switch A
Switch B
S
witch B successfully
receives traffic from
Switch A on this port.
98648
However, Switch A does not receive traffi
c
from Switch B on the same port. If UDLD
is in aggressive mode, it detects the
problem and disables the port. If UDLD is
in normal mode, the logical link is
considered undetermined, and UDLD
does not disable the interface.