32-13
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter32 Configuring SNMP Configuring SNMP
Note Though visible in the command-line help strings, the cpu [ threshold] keyword is not supported. Though
visible in the command-line help strings, the cpu [threshold], fru-ctrl, insertion, and removal
keywords are not supported on the nonstackable switch. To enable the sending of SNMP inform
notifications, use the snmp-server enable traps global configuration command combined with the
snmp-server host host-addr informs global configuration command.
You can use the snmp-server host global configuration command to a specific host to receive the
notification types listed in Table32-5.
Beginning in privileged EXEC mode, follow these steps to configure the switch to send traps or informs
to a host:
vlan-membership Generates a trap for SNMP VLAN membership changes.
vlancreate Generates SNMP VLAN created traps.
vlandelete Generates SNMP VLAN deleted traps.
vtp Generates a trap for VLAN Trunking Protocol (VTP) changes.
Table32-5 Switch Notification Types (continued)
Notification Type
Keyword Description
Command Purpose
Step1 configure terminal Enter global configuration mode.
Step2 snmp-server engineID remote
ip-address engineid-string Specify the engine ID for the remote host.
Step3 snmp-server user username
groupname {remote host [udp-port
port]} {v1 [access access-list] | v2c
[access access-list] | v3 [encrypted]
[access access-list] [auth {md5 | sha}
auth-password]}
Configure an SNMP user to be associated with the remote host created in
Step 2.
Note You cannot configure a remote user for an address without first
configuring the engine ID for the remote host. Otherwi se, you
receive an error message, and the command is not executed.
Step4 snmp-server group groupname {v1 |
v2c | v3 {auth | noauth | priv}} [read
readview] [write writeview] [notify
notifyview] [access access-list]
Configure an SNMP group.