fn = 4: Function 4 Sending the Set Memory Switch Value

GS (E pL pH fn a fn = 4

[Code]

<1d>H<28>H<45>pL pH fn a

 

 

[Range]

(pL + pH 256) = 2

 

 

 

fn = 4

 

 

 

a = 1, 2, 3, 4

 

 

[Outline]

• Sends the content of memory switch set in “a”.

 

 

 

 

 

 

 

 

 

Hex.

No. of Data

 

Header

 

37H

1

 

 

 

 

 

 

ID

 

21H

1

 

Data

 

30H or 31H

8

 

NULL

 

00H

1

Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6, ....

OFF: 30H (“0”)

ON : 31H (“1”)

— 95 —