fn = 5: Function 5 Setting Customized Value
GS (E pL pH fn [a1 n1L n1H]...[ak nkL nkH] fn = 5
[Code] | <1d>H<28>H<45>pL pH fn [a1 n1L n1H]...[ak nkL nkH] | |||
[Range] | 4 (pL + pH ⋅ 256) | 65535 | ||
| fn = 5 |
|
|
|
| 1 a 3 a = 5, 6, 97, 116, 201, 202 | |||
| 1 (nL + nH ⋅ 256) | 65535 | ||
[Default] | Described in the processing table for “a”. | |||
[Outline] | • Sets the customized value set in “a” to (nL + nH ⋅ 256). | |||
|
|
|
|
|
| a |
|
| Function |
| 3 | Selects paper width. | ||
| 5 | Selects printing density. | ||
| 6 | Selects printing speed. | ||
| 97 | Selects the number of divisions for conducting head. | ||
| 116 | Selects printing color. | ||
|
|
|
| |
| 201 | Sets ACK output position (only parallel I/F). | ||
| 202 | Selects input buffer full Busy output/cancel timing (idle capacity). | ||
| • a = 3: Sets paper width to the size specified by (nL + nH ⋅ 256). | |||
|
|
|
| |
| (nL + nH ⋅ 256) |
| Paper Width | |
| 2 |
|
| 58 mm |
| 3* |
|
| 60 mm |
| 6 (Default) |
| 80 mm |
*No function with
•a = 5: Sets printing density to the level specified by (nL + nH ⋅ 256).
(nL + nH ⋅ 256) | Printing Density | |
65530 | 0.7 times | |
|
| |
65531 | 0.75 times | |
65532 | 0.8 times | |
65533 | 0.85 | times |
65534 | 0.9 times | |
65535 | 0.95 | times |
0 (Default) |
| 1 |
1 | 1.05 | times |
2 | 1.1 | times |
3 | 1.25 | times |
4 | 1.2 | times |
5 | 1.25 | times |
6 | 1.3 | times |
|
|
|
7 | 1.35 | times |
8 | 1.40 | times |
— 96 —