fn = 49: Function 49 Setting Printing Density

GS (K pL pH fn m fn = 49

[Code]

<1d>H<28>H<4B>pL pH fn m

[Range]

(pL + pH 256) = 2 : (pL = 2, pH = 0)

 

fn = 49

 

 

0 m 9, 250 m

255

[Default]

m = 0 (Customized value setting value)

[Outline]

Sets printing density.

 

 

 

 

 

 

m

 

Printing Density

 

250

 

Selects density level –6 (70%)

 

251

 

Selects density level –5 (75%)

 

252

 

Selects density level –4 (80%)

 

253

 

Selects density level –3 (85%)

 

254

 

Selects density level –2 (90%)

 

255

 

Selects density level –1 (95%)

 

0

 

Selects standard density (100%)

 

1

 

Selects density level + 1 (105%)

 

2

 

Selects density level + 2 (110%)

 

3

 

Selects density level + 3 (115%)

 

4

 

Selects density level + 4 (120%)

 

5

 

Selects density level + 5 (125%)

 

6

 

Selects density level + 6 (130%)

 

7

 

Selects density level + 7 (135%)

 

8

 

Selects density level + 8 (140%)

— 110 —