fn = 11: Function 11 Setting Communication Conditions of Serial

Interface

GS (E pL pH fn a d1...cdk fn = 11

[Code]

<1d>H<28>H<45>pL pH fn a d1..dk

[Range]

3

(pL + pH 256) 65535 (0 pL 255, 0 pH 255)

 

fn = 11

 

1

a 4 (Not changed in other than specified range)

 

48

d 57 (Not changed in other than specified range)

 

1

k 6

[Outline]

Sets the communication conditions of serial interface specified by “a”.

 

 

• a = 1: Setting baud rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate

 

d1

 

d2

 

d3

d4

d5

d6

 

2400

50 (“2”)

 

52 (“4”)

48

(“0”)

48 (“0”)

 

4800

52 (“4”)

 

56 (“8”)

48

(“0”)

48 (“0”)

 

9600

57 (“9”)

 

54 (“6”)

48

(“0”)

48 (“0”)

 

19200

49 (“1”)

 

57 (“9”)

50

(“2”)

48 (“0”)

48 (“0”)

 

(Default)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38400

51 (“3”)

 

56 (“8”)

52

(“4”)

48 (“0”)

48 (“0”)

 

• a = 2: Setting to specified parity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d1

 

 

 

 

 

 

Parity Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48 (Default)

 

 

 

No parity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49

 

 

 

 

 

 

 

Odd parity

 

 

 

50

 

 

 

 

 

 

 

Even parity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• a = 3: Setting to specified flow control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d1

 

 

 

 

 

 

Flow Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48 (Default)

 

 

 

 

 

 

 

DSR/DTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49

 

 

 

 

 

 

 

XON/XOFF

 

 

 

• a = 4: Setting to specified data length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d1

 

 

 

 

 

Setting Data Length

 

 

 

55

 

 

 

 

 

 

 

7-bit length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56 (Default)

 

 

8-bit length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operates only in printer function setting mode.