GS ^ n1 n2 n3

[Function]

Executing the macro

[Code]

<1D>H<5E>H<n1><n2><n3>

[Range]

0

n1

255

 

0

n2

255

 

0

n3

1

[Outline]

Executing contents defined in macro.

 

n1 : The number of times of macro execution

 

n2 : Waiting time on macro execution: Waiting time of n2 100 msec is given for

 

every execution.

 

n3 : Macro execution mode

 

n3 = 0 Continuous execution: The Macro is executed “n1” times continuously at the

 

time interval specified by “n2”.

 

n3 = 1 Execution by FEED Switch: After waiting for the time specified by “n2”, the

 

ARARM LED flickers and the FEED switch is waiting to be pressed. When it is pressed,

 

the macro is executed once. This action is repeated “n1” times.

[Caution]

• When this command is received while in macro definition, suspension of macro

 

 

definition is indicated. At this time, the defined content is cleared.

 

• No execution takes place when the macro is held undefined.

 

• While in macro execution with n3 = 1, paper feed with the FEED switch is not

 

 

available.

[See Also]

GS :

 

[Sample Program]

Refer to Sample Program and Print Results for GS:.

— 64 —

Page 69
Image 69
Citizen CT-S300 manual GS n1 n2 n3