fn = 1: Function 1 Transferring to Printer Function Setting Mode

GS (E pL pH fn d1 d2 fn = 1

[Code]

<1d>H<28>H<45>pL pH fn d1 d2

 

[Range]

(pL + pH 256) = 3

(pL = 3, pH = 0)

 

 

fn = 1

 

 

 

 

d1 = 73 (“I”)

 

 

 

 

d2 = 78 (“N”)

 

 

 

[Outline]

Transfers to printer function setting mode and sends the report of mode transfer.

 

 

 

 

 

 

 

 

Hex.

No. of Data

 

Header

 

37H

1

 

ID

 

20H

1

 

NULL

 

00H

1

— 90 —