DLE DC4 fn m t (Specification of fn = 1)
[Function] | Outputting specified pulse in | |
[Code] | <10>H<14>H<fn><m><t> |
|
[Range] | fn = 1, 0 m 8, 1 t | 8 |
[Outline] | • A signal specified with “t” is output to the connector pin specified with “m”. | |
|
|
|
| m | Connector Pin |
0Pin No. 2 of drawer
1Pin No. 5 of drawer
•Set the ON time/OFF time to t ⋅ 100 ms, respectively.
[Caution] | • When receiving a code row coinciding with the code configuring this command, |
| the same operation as this command takes place and attention by the user is |
| required. |
| Example: When corresponding code row is present in bit image data. |
| • This command must not be used between other command code rows. |
| Example: This command is used in the bit image data. |
| • This command is ignored under the following conditions. |
| • During sending block data |
| • During output of signal to drawer kick connector |
| • During occurrence of error |
[See Also] | ESC p |