ESC p m n1 n2
[Function] | Generating the specified pulses |
[Code] | <1B>H<70>H<m><n1><n2> |
[Range] | m = 0, 1, 48, 49 |
| 0 < n1 n2 255 |
[Outline] | • The signals specified by “n1” and “n2” are output to the connector pin specified by |
| “m”. |
| • “m” has the followings. |
m
0, 48
1, 49
Connector Pin
Drawer
Drawer
• The ON time is n1 ⋅ 2 ms, and OFF time n2 ⋅ 2 ms.
[Caution] | • When “m” is beyond a definition range, no signal is output, discarding “n1” and | |||
| “n2”. |
|
| |
| • The drawer drive duty must be within the following range: | |||
|
| ON time | 0.2 | |
|
| ON time + OFF time | ||
|
|
| ||
| (The OFF time should be 4 times or more longer than the ON time.) | |||
[Sample Program] |
|
|
|
|
| LPRINT CHR$(&H1B) + "p" |
| ||
| LPRINT CHR$(0); | ← Selects pin No. 2. | ||
| LPRINT CHR$(5); | ← Sets ON time to 10 ms | ||
| LPRINT CHR$(50); | ← Sets OFF time to 100 ms |
— 124 —