DLE DC4 fn d1...d7 (Specification of fn = 8)

[Function]

Buffer clear

 

 

 

[Code]

<10>H<14>H<fn><d1> ...<d7>

 

 

[Range]

fn = 8, d1 = 1, d2 = 3, d3 = 20, d4 = 1, d5 = 6, d6 = 2, d7 = 8

 

[Outline]

• Erases all data in receiving buffer or print buffer.

 

 

• Sends the following 3-byte data group.

 

 

 

 

 

 

 

 

 

Hex.

Decimal

No. of Data

 

Header

37H

55

1 byte

 

Identifier

25H

37

1 byte

 

NULL

00H

0

1 byte

• Enters the state of selecting STANDARD MODE.

[Caution]

• When receiving a code row coinciding with the code configuring this command,

 

the same operation as this command takes place and attention by the user is

 

required.

 

Example: When corresponding code row is present in bit image data.

 

• This command must not be used between other command code rows.

 

Example: This command is used in bit image data.

 

• This command is ignored during transmission of block data.

[See Also]

ESC p

— 119 —

Page 124
Image 124
Citizen CT-S300 manual DLE DC4 fn d1...d7 Specification of fn =, Hex Decimal No. of Data