fn = 6: Function 6 Sending the Set Customized Value

GS (E pL pH fn a fn = 6

[Code]

<1d>H<28>H<45>pL pH fn a

 

 

 

 

 

 

 

[Range]

(pL + pH 256) = 2 : (pL = 2, pH = 0)

 

 

 

 

 

 

 

 

fn = 6

 

 

 

 

 

 

 

 

 

 

1 a 3, a = 5, 6, 97, 116, 201, 202

 

 

 

 

 

 

 

[Outline]

• Sends the set value of customized value set by “a”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex.

 

No. of Data

 

 

Header

 

 

37H

 

 

 

1

 

 

ID

 

 

27H

 

 

 

1

 

 

Customized value No.

 

30H ~ 39H

 

1 ~ 3

 

 

Separation number

 

1FH

 

 

 

1

 

 

Customized value

 

30H ~ 39H

 

1 ~ 5

 

 

NULL

 

 

00H

 

 

 

1

 

• Configuration of customized value No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a

 

 

Sending Data

 

 

 

 

 

1st Byte

2nd Byte

 

3rd Byte

 

 

 

 

 

 

3

 

51 (“3”)

 

 

 

 

5

 

53 (“5”)

 

 

 

 

6

 

54 (“6”)

 

 

 

 

97

 

57 (“9”)

55 (“7”)

 

 

 

116

 

49 (“1”)

49 (“1”)

 

54 (“6”)

 

201

 

50 (“2”)

48 (“0”)

 

49 (“1”)

 

202

 

50 (“2”)

48 (“0”)

 

50 (“2”)

 

• a = 3: When paper width is specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting Status

 

Sending Data

 

 

 

 

 

Stored

 

Power

1st Byte

2nd Byte

 

3rd Byte

 

4th Byte

 

5th Byte

 

 

Value

 

Width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

58 mm

49 (“1”)

 

 

 

 

 

2*

 

60 mm

50 (“2”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

80 mm

51 (“3”)

 

 

 

* No function with CT-S300

— 98 —

Page 103
Image 103
Citizen CT-S300 manual 1FH, Sending Data 1st Byte 2nd Byte 3rd Byte