Safety

4.Combis must never be used to cook foodstuffs in sealed containers not designed for this purpose. (Combis are excellent for “purpose built” containers such as sous vide packages.)

5.Combis must never be used to heat flammable items such as oils, fats, cloths, or similar items.

6.Combis must never be used to heat non-food items (except suitable appliance accessories).

D. Gas Supply and Electricity Supply

1.The installer / owner is responsible for furnishing and installing gas supply lines, valves, regulators, and accessories (Gas Combis.)

2.The installer / owner is responsible for furnishing all electrical lines and accessories.

3.When installing gas and / or electric supply lines and accessories, observe the following:

a.The gas supply type must match the type of gas specified on the rating plate. (Gas Combis.)

b.The electricity supply must match all electrical and wiring requirements specified on the rating plate.

c.For further information regarding gas and electricity supply: refer to the Installation Manual.

d.For gas Combis: Obtain and post gas leak procedure instructions in a prominent location. These instructions may be obtained from your gas supplier.

4.The installation of this Combi must conform with:

a.The Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA)

b.The National Fuel Gas Code, ANSI Z223.1 / NFPA 54 (latest edition) or the Natural Gas and Propane Installation Code CSA B1 49.1 as applicable. (Gas Combis).

c.The National Electrical Code, ANSI/NFPA 70 (latest edition) or the Canadian Electrical Code, CSA C22.2 as applicable.

d.The Food Service Sanitation Manual of the Food and Drug Administration (FDA).

e.All applicable state and local laws, codes, and regulations.

f.If any pressure testing is required: The Combi must be isolated from the gas supply system during any pressure testing as follows:

HIGH PRESSURE TESTING: The COMBI and its main manual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 14” Water Column (1/2 psi or 3.45kPa). Leak test all joints and fittings with soap and water solution after reconnecting gas supply

LOW PRESSURE TESTING: The COMBI must be isolated from the gas supply piping system by closing its main manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 14” water column (1/2 psi or 3.45kPa) Leak test all joints and fittings with soap and water solution after opening the main manual shut-off valve.