Maintenance and Cleaning
Semi-automatic cleaning of oven chamber
The Convotherm by Cleveland has a
1.Always wear appropriate protective clothing and equipment when using this Sprayer, including protective gloves and goggles.
2.Press the Smart Key . Various options appear in the display.
3.Use the Selector Dial to select “Cleaning” .
4.Confirm by pressing the Smart Key .
5.Confirm “Yes” with the Smart Key .
6.The display will show the nominal values for the cleaning cooking mode. a. 158°F for 10 minutes in Hot Air mode.
7.Press the Smart Key The cleaning process will start.
8.After the first signal, open the oven door, spray the oven chamber, base outflow, grills, plates etc. with original Convotherm by Cleveland CONVOClean forte or new, using the Hand Sprayer, P/N 111598.
9.Close the door and allow the CONVOClean to take effect.
10. Do NOT press the Start / Stop key | again. |
11.The cleaning cooking mode will continue automatically.
a.86°F for 10 minutes in Steam mode.
12.After the second signal, clean thoroughly behind the suction plate. Clean the suction plate (fan guard) and the fan area behind the suction plate at the same time.
a.Release the
b.Pivot the oven racks and suction plate (fan guard) out into the oven chamber.
c.After cleaning, push the oven racks and suction plate (fan guard) closed and fix it in place with the
13.After the next signal, run Combi mode with Crisp ‘n’ Tasty at level 3 (High) at 212°F for 10 minutes.
14.Turn OFF the Combi.
15.Use the hand shower to rinse the oven chamber, accessories, and behind the suction plate thoroughly.
16.In the case of severe staining or soiling, repeat the cleaning process.
17.After the Combi is clean: repeat steps
18.After use or after cleaning, leave the Combi door open.
Automatic cleaning system (optional):
1.The oven chamber must be cold before starting this process.
2.Before starting, remove large pieces food or cooking residue from the oven chamber. This will help prevent the drain from becoming blocked.
3.Check the level of Convotherm by Cleveland CONVOClean and CONVOCare.
a.The containers must be full.
b.The suction pipes must be located in the fluid.
4.Press the Smart Key . Various options will appear in the display.
5.Use the Selector Dial to select “CONVOClean system” .
6.Confirm by pressing the Smart Key .
73