Compaq M300 manual 15-12Troubleshooting, Solving Infrared Problems

Models: M300

1 195
Download 195 pages 10.06 Kb
Page 140
Image 140

15-12Troubleshooting

Solving Infrared Problems Continued

 

Interrupt request

Check IRQ assignments for conflicts,

 

(IRQ) conflict.

then reassign if necessary.

 

 

See Appendix C for IRQ port

 

 

information.

 

 

 

 

Baud rate, # bits,

Select the same baud rate, # bits, stop

 

stop byte, or parity

byte, and parity setting for both

 

conflict.

devices.*

 

 

 

 

A physical condition

Refer to “Data transmission problem”

 

exists that affects

in this table.

 

the connection.

 

 

 

 

System does not

The system cannot

To disable Infrared Monitor search,

initiate Suspend while

initiate Suspend

select StartSettingsControl

infrared port is

while Infrared

PanelInfraredOptions tab, then

enabled.

Monitor search is

remove the check from the Search for

 

enabled.

and Provide Status for Devices in

 

 

Range check box.

 

 

 

Data transmission

Direct sunlight,

Remove the interfering

problem.

energy-saving

light source(s).

 

fluorescent light, or

Move the infrared ports closer

 

flashing

 

together.

 

incandescent light is

 

 

 

close to the infrared

Select a slower fixed baud rate for both

 

connections.

devices.*

 

 

 

 

Interference from

Keep infrared-equipped remote control

 

other

units, such as wireless headphones,

 

infrared-equipped

pointed away from the infrared

 

devices.

connection.

 

 

 

 

Dirty infrared lens.

Clean the lens with a lint-free cloth.

 

 

 

 

Distance.

Verify that the infrared ports are not

 

 

more than 1.5 feet (0.5 meter) apart.