INPUT TEST

The Input Test verifies the function of inputs available on the various models of the microKool chiller. Not all inputs are used on all models. The performance evaluation of the inputs is based on the voltage sensing device (VSD).

INPUT TEST

1

Connect all inputs to the system.

 

 

 

2

Press any key to display the first test menus.

 

 

 

3

Select the Input Test menu.

 

Press and hold the Setpoint

 

key for 3 seconds to index

to each test menu until the controller displays “InP”.

4

Repeatedly press and release any key to test.

With each key press and release, the left display will indi- cate the number of the input being tested (v1, v2, v3, etc.). The right display indicates either “1” for voltage present or “O” for an absence of voltage.

Only inputs that are actually used by the particular model will be tested.

5

Exit the test and enter the next test.

Press and hold the Setpoint Connect all inputs to the system. key for 3 seconds to exit and index to the next test.