Programming Parameters

 

 

 

 

 

Defaults

 

Scanner Type

 

 

I.

Accep-

 

 

 

 

 

 

Code Parameter/ Description

 

 

 

 

Laser/

2D

D.

table

 

 

 

Fac-

 

 

#

Input

Min

Max

 

Linear

Imag

 

 

 

tory

 

 

 

 

 

 

 

Imager

er

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructs the decoder to transmit

0

 

 

 

 

 

 

 

 

the decoded start and stop charac-

 

 

 

 

 

 

 

Send Start/

3

On or

 

 

 

 

9

9

ters of Codabar labels. The start

Off

On

 

Off

Stop

0

Off

 

and stop characters will both be

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

translated as A, B, C, or D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restricts the Codabar decoder to

 

 

 

 

 

 

 

 

 

only read labels that conforms to

0

 

 

 

 

 

 

 

Convert to

CLSI specifications. Label length

3

On or

Off

Off

 

Off

9

 

CLSI

must be 14, and the data is split

0

Off

 

 

 

 

 

 

 

 

 

into fields of 1, 4, 5, and 4 charac-

6

 

 

 

 

 

 

 

 

ters separated by spaces.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allow Wide

 

0

 

 

 

 

 

 

 

Allows wide gaps to appear

3

On or

Off

On

 

On

9

 

Interchar-

 

 

between characters in a label.

0

Off

 

 

acter Gaps

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

Set the minimum label length to be

0

 

 

 

 

 

 

 

3

 

 

 

 

 

9

9

Label

less than or equal to maximum

01 - 50

01

01

 

04

2

 

Length

label length.

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This feature specifies the maximum

 

 

 

 

 

 

 

 

Maximum

allowable length of a Codabar label.

0

 

 

 

 

 

 

 

The length includes check and data

3

01 - 50

01

50

 

20

9

9

Label

 

characters. Maximum Label Length

2

 

Length

 

 

 

 

 

 

 

should be greater than or equal to

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Label Length.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the number of times a label

0

 

 

 

 

 

 

 

Read Veri-

3

 

 

 

 

 

9

 

must be read before it is transmit-

01 - 04

01

02

 

01

 

fication

2

 

 

ted.

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-4