Programming Parameters

 

 

 

 

 

 

Defaults

 

Scanner Type

 

 

 

I.

Accep-

 

 

 

 

 

 

Code Parameter/ Description

 

 

 

 

 

Laser/

2D

 

D.

table

 

 

 

Fac-

 

 

 

#

Input

Min

Max

 

Linear

Imag

 

 

 

 

tory

 

 

 

 

 

 

 

 

Imager

er

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the number of times a label

 

0

 

 

 

 

 

 

 

Read Veri-

 

5

 

 

 

 

 

9

 

must be read before it is transmit-

 

01 - 04

01

02

 

01

 

fication

 

2

 

 

ted.

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifies the symbology identifier

 

 

Any

 

 

 

 

 

 

 

 

 

single

 

 

 

 

 

 

 

(if any) sent when parameter Send

 

0

 

 

 

 

 

 

 

 

ASCII

 

 

 

 

 

 

 

Code ID (Index 0025) is set to 3.

 

5

 

 

 

 

9

9

User ID

 

charac-

'A'

'A'

 

'A'

ASCII code zero (null) is used to

 

2

 

 

 

ter

 

 

 

 

 

 

 

indicate that an identifier is not to

 

1

 

 

 

 

 

 

 

 

(00 =

 

 

 

 

 

 

 

be sent for the symbology.

 

 

 

 

 

 

 

 

 

 

 

Off)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Universal Product Code-E (UPC-

 

 

Enter 1 for On

 

 

 

E)

 

 

 

 

and 0 for Off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

 

0

 

 

 

 

 

 

 

Enables/disables UPC-E labels

 

5

On or

Off

On

 

On

9

9

System

 

 

with a system digit of zero.

 

0

Off

 

Digit 0

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

Enables more aggressive decoding

 

0

 

 

 

 

 

 

 

Aggres-

 

5

On or

 

 

 

 

9

 

algorithms to be used in order to

 

Off

On

 

Off

 

sive

 

0

Off

 

 

scan hard to read labels.

 

 

 

 

 

 

 

Decoding

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send

 

 

0

 

 

 

 

 

 

 

Includes the check digit in the label

 

5

On or

Off

On

 

Off

9

9

Check

 

 

which is transmitted.

 

0

Off

 

Digit

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This instructs the decoder to

 

0

 

 

 

 

 

 

 

Send Sys-

include the system digit in the label

 

5

On or

Off

On

 

Off

9

9

tem Digit

transmission. For UPC-E, the sys-

 

0

Off

 

 

 

 

 

 

 

 

 

tem digit is zero.

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-22