Programming Parameters

 

 

 

 

 

Defaults

 

Scanner Type

 

 

I.

Accep-

 

 

 

 

 

 

Code Parameter/ Description

 

 

 

 

Laser/

2D

D.

table

 

 

 

Fac-

 

 

#

Input

Min

Max

 

Linear

Imag

 

 

 

tory

 

 

 

 

 

 

 

Imager

er

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code 128

 

 

Enter 1 for On

 

 

 

 

 

 

 

and 0 for Off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

Enable

Enables/disables the Code 128

4

On or

Off

On

 

On

9

9

symbology.

0

Off

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

Enables more aggressive decoding

0

 

 

 

 

 

 

 

Aggres-

4

On or

 

 

 

 

9

 

algorithms to be used in order to

Off

On

 

Off

 

sive

0

Off

 

 

scan hard to read labels.

 

 

 

 

 

 

Decoding

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructs the decoder to recognize

 

 

 

 

 

 

 

 

 

UCC-128 versions of Code 128

0

 

 

 

 

 

 

 

Enable

labels and process them differently

 

 

 

 

 

 

 

4

On or

 

 

 

 

9

9

UCC/EAN-

by changing the Code ID, and

Off

On

 

Off

0

Off

 

128

replacing each occurrence of the

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

FNC1 character with GS (ASCII

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29) characters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructs the decoder to concate-

0

 

 

 

 

 

 

 

ISBT Con-

4

On or

 

 

 

 

9

9

nate Code 128 labels conforming to

Off

Off

 

 

catenation

0

Off

 

 

the ISBT 128 standard.

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

Set the minimum label length to be

0

 

 

 

 

 

 

 

4

 

 

 

 

 

9

9

Label

less than or equal to maximum

01 - 50

01

01

 

02

2

 

Length

label length.

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This feature specifies the maximum

 

 

 

 

 

 

 

 

 

allowable length of a Code 128

0

 

 

 

 

 

 

 

Maximum

label. The length includes check

 

 

 

 

 

 

 

4

 

 

 

 

 

9

9

Label

and data characters. Maximum

01 - 50

01

50

 

20

2

 

Length

Label Length should be greater

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

than or equal to Minimum Label

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-8

Falcon® 4400 Series with Windows® CE