Bar Code Parameters

 

 

 

 

Defaults

 

Scanner Type

 

I.

Accep-

 

 

 

 

 

 

Code Parameter/ Description

 

 

 

 

Laser/

2D

D.

table

 

 

 

Fac-

 

#

Input

Min

Max

 

Linear

Imag

 

 

tory

 

 

 

 

 

 

Imager

er

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

European Article Numbering-8

 

 

Enter 1 for On

 

 

 

(EAN-8)

 

 

 

and 0 for Off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

Enable

 

Enables/disables the EAN-8 sym-

5

On or

Off

On

On

9

9

 

bology.

1

Off

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

Enables more aggressive decoding

0

 

 

 

 

 

 

Aggres-

 

5

On or

 

 

 

9

 

 

algorithms to be used in order to

Off

On

Off

 

sive

 

1

Off

 

 

scan hard to read labels.

 

 

 

 

 

Decoding

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send

 

Instructs the terminal to include the

0

 

 

 

 

 

 

 

5

On or

 

 

 

9

9

Check

 

check digit in the label transmis-

Off

On

Off

 

1

Off

Digit

 

sion.

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Convert

 

Instructs the decoder to expand

0

 

 

 

 

 

 

 

EAN-8 labels to their EAN-13

5

On or

Off

On

Off

9

 

EAN-8 to

 

 

 

equivalents. Any EAN-13 parame-

1

Off

 

EAN-13

 

 

 

 

 

 

 

ters will then apply to the result.

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the number of times a label

0

 

 

 

 

 

 

Read Veri-

 

5

 

 

 

 

9

 

 

must be read before it is transmit-

01 - 04

01

02

01

 

fication

 

2

 

 

ted.

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifies the symbology identifier

 

Any

 

 

 

 

 

 

 

(if any) that is sent by the decoder

0

single

 

 

 

 

 

 

 

when parameter Send Code ID

ASCII

 

 

 

 

 

 

 

5

 

 

 

9

9

User ID

 

(Index 0025) is set to 3. ASCII

charac-

'G'

'G'

'G'

 

2

 

 

code zero (null) is used to indicate

ter

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

that an identifier is not to be sent for

(00 =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the symbology.

 

Off)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 