System Outline
Charge Voltage (MHV)
Input Voltage : 24 V DC
15%
Output Voltage :
3%
Output Voltage Rising Time : 50 ms Max
Output Voltage Falling Time : 50 ms Max
Output Control
Cleaning Voltage
The (+) Transfer Voltage is not outputted because the THV PWM is controlled with high.
The
The output fluctuation range is big because there is no Feedback control.
Developing Voltage (DEV) |
|
|
Input Voltage : 24 V DC | 15% |
|
Output Voltage: | 3% | |
Output Voltage Fluctuation Method : PWM Control | ||
Line Regulation : under | 3% (fluctuation input 21.6V ~ 27.6V) | |
Load Regulation : Under | 3% |
|
Output Voltage Rising Time : 50 ms Max
Output Voltage Falling Time : 50 ms Max
Output Control Signal
Supply
Output Voltage :
5% (ZENER using, DEV )
Line Regulation : under | 3% (fluctuation input 21.6V ~ 27.6V) |
Load Regulation : Under | 3% |
Output Voltage Rising Time : 50 ms Max
Output Voltage Falling Time : 50 ms Max
Output Control Signal
Service Manual