Alignment & Adjustments
6.5.3 Detail Description(Engine Test Mode)
Function Name | Description | Display |
01.Motor Test | The main motor keeps running after the execution key is | Main Motor On(Off) |
| chosen and stops when the stop key is chosen. |
|
|
|
|
02.Pick Up Test | automatically | Tray 1,2 Solenoid On/Off |
| stops, when the execution is chosen. |
|
03.Fan Test | The fan keeps running after the execution key is chosen | Fan On(Off) |
| and stops when the stop key is chosen. |
|
04.Manual Clutch Test | The tray2,3 clutch is on for 1sec and then it automatically | Tray 2,3 Clutch On/Off |
| stops, when the execution is chosen.On this function, |
|
| the main motor runs before 2sec from the point of the clutch |
|
| on in order to check the clutch state. |
|
05.PTL Test | PTL On(Off) | |
| chosen and it stops when the stop key is chosen. |
|
11.LSU Motor | Test The laser motor keeps running after the execution key | Laser Motor On(Off) |
| is chosen and stops when the stop key is chosen. |
|
12.LSU Hsync Test | “Laser Leady” is displayed, When the Laser Scanning | Laser Leady On(Off) |
| Unit is ready to print. On the other case “Laser Error” |
|
13.LD Test | “Diode On” is displayed, when the laser diode is on. | Diode On(Off) |
| On the other case “Diode Off” is displayed. |
|
21.Feed Sen Test | These Functions are considered to check the present | "Sensor Off"to “ Sensor On ” |
22.Exit Sen Test | state (normal or not)of the Sensors. |
|
23.Cover Sen Test | After the cover is open, touch the sensor and confirm | "Cover Open" to "Cover Close" |
| the message changed “Cover Open” to “ Cover Close” |
|
24.Empty Sen Test | These Functions are considered to check the present | "Sensor Off"to “ Sensor On ” |
25.Manual Sen Test | state (normal or not)of the Sensors. |
|
31.Them ADC 180 | “current value"is displayed on the upper line of the panel, | Input and output value are |
32.Them ADC 140 | and “target value"on the bottom line. | ADC value.(refer to the |
33.Them ADC 120 | Target value is limited from “191°C” to “80°C” | ADC table) |
34.Them ADC 100 |
|
|
41.MHV Test | These Functions are considered to check whether the | MHV On(Off) |
42.Dev Bias Test | control for HVPS is normal or not. | Dev Bias On(Off) |
43.THV EN/NEG Test |
| THV EN/NEG On(Off) |
44.THV ON(1300V) |
| THV On(Off) |
45.THV ADC 1300V |
| ADC value displayed. |
46.THV ADC 600V~3500 |
| ADC value displayed. |