Alignment & Adjustments

6.5.3 Detail Description(Engine Test Mode)

Function Name

Description

Display

01.Motor Test

The main motor keeps running after the execution key is

Main Motor On(Off)

 

chosen and stops when the stop key is chosen.

 

 

 

 

02.Pick Up Test

automatically

Tray 1,2 Solenoid On/Off

 

stops, when the execution is chosen.

 

03.Fan Test

The fan keeps running after the execution key is chosen

Fan On(Off)

 

and stops when the stop key is chosen.

 

04.Manual Clutch Test

The tray2,3 clutch is on for 1sec and then it automatically

Tray 2,3 Clutch On/Off

 

stops, when the execution is chosen.On this function,

 

 

the main motor runs before 2sec from the point of the clutch

 

 

on in order to check the clutch state.

 

05.PTL Test

PTL(Pre-Transfer Lamp) is on after the execution key is

PTL On(Off)

 

chosen and it stops when the stop key is chosen.

 

11.LSU Motor

Test The laser motor keeps running after the execution key

Laser Motor On(Off)

 

is chosen and stops when the stop key is chosen.

 

12.LSU Hsync Test

“Laser Leady” is displayed, When the Laser Scanning

Laser Leady On(Off)

 

Unit is ready to print. On the other case “Laser Error”

 

13.LD Test

“Diode On” is displayed, when the laser diode is on.

Diode On(Off)

 

On the other case “Diode Off” is displayed.

 

21.Feed Sen Test

These Functions are considered to check the present

"Sensor Off"to “ Sensor On ”

22.Exit Sen Test

state (normal or not)of the Sensors.

 

23.Cover Sen Test

After the cover is open, touch the sensor and confirm

"Cover Open" to "Cover Close"

 

the message changed “Cover Open” to “ Cover Close”

 

24.Empty Sen Test

These Functions are considered to check the present

"Sensor Off"to “ Sensor On ”

25.Manual Sen Test

state (normal or not)of the Sensors.

 

31.Them ADC 180

“current value"is displayed on the upper line of the panel,

Input and output value are

32.Them ADC 140

and “target value"on the bottom line.

ADC value.(refer to the

33.Them ADC 120

Target value is limited from “191°C” to “80°C”

ADC table)

34.Them ADC 100

 

 

41.MHV Test

These Functions are considered to check whether the

MHV On(Off)

42.Dev Bias Test

control for HVPS is normal or not.

Dev Bias On(Off)

43.THV EN/NEG Test

 

THV EN/NEG On(Off)

44.THV ON(1300V)

 

THV On(Off)

45.THV ADC 1300V

 

ADC value displayed.

46.THV ADC 600V~3500

 

ADC value displayed.

6-18Service Manual

Page 88
Image 88
Dell 1815DN service manual Detail DescriptionEngine Test Mode, Laser Motor OnOff