About Your System 21
E1410 CPU # IERR Specified microprocessor is
reporting an internal error.
See your system’s Information
Update Tech Sheet located on
support.dell.com for the most
current system information. If
problem persists, see "Getting
Help" on page147.
E1414 CPU # Thermtrip Specified microprocessor is out of
acceptable temperature range and
has halted operation.
See "Troubleshooting System
Cooling Problems" on page119.
If the problem persists, ensure
that the microprocessor heat
sinks are properly installed. See
"Troubleshooting the
Microprocessors" on page128.
NOTE: The LCD continues to
display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these utilities.
E1418 CPU # Presence Specified processor is missing or
bad, and the system is in an
unsupported configuration.
See "Troubleshooting the
Microprocessors" on page128.
E141C CPU Mismatch Processors are in a configuration
unsupported by Dell.
Ensure that your processors
match and conform to the type
described in the Microprocessor
Technical Specifications outlined
in your system’s Getting Started
Guide.
E141F CPU Protocol The system BIOS has reported a
processor protocol error.
See "Getting Help" on page147.
E1420 CPU Bus PERR The system BIOS has reported a
processor bus parity error.
See "Getting Help" on page147.
E1421 CPU Init The system BIOS has reported a
processor initialization error.
See "Getting Help" on page147.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 21 Friday, February 3, 2006 11:09 AM