System Messages

System messages appear on the screen to notify you of a possible problem with the system. Table 1-3 lists the system messages that can occur and the probable cause and corrective action for each message.

NOTE: If you receive a system message that is not listed in Table 1-3, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Table 1-7. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! Redundant memory

Installed memory modules are not the

Ensure that all memory modules are of

disabled! Memory

same type and size; faulty memory

the same type and size and that they are

configuration does not

module(s).

properly installed. If the problem

support redundant memory.

 

persists, see "Troubleshooting System

 

 

Memory" on page 120.

 

 

 

Attempting to update

Remote Configuration request has

Wait until the process is complete.

Remote Configuration.

been detected and is being processed.

 

Please wait...

 

 

 

 

 

BIOS Update Attempt

Remote BIOS update attempt failed.

Retry the BIOS update. If problem

Failed!

 

persists, see "Getting Help" on page 147.

 

 

 

Caution! NVRAM_CLR jumper

NVRAM_CLR jumper is installed.

Remove NVRAM_CLR jumper. See

is installed on system

CMOS has been cleared.

Figure 6-1 for jumper location.

board.

 

 

 

 

 

CPUs with different cache

Microprocessors with different cache

Ensure that all microprocessors have the

sizes detected!

sizes are installed.

same cache size and that they are

 

 

properly installed. See "Processors" on

 

 

page 93.

 

 

 

Decreasing available

Faulty or improperly installed memory

See "Troubleshooting System Memory"

memory

modules.

on page 120.

 

 

 

DIMM pairs must be matched

Mismatched or unmatched DIMMs

Ensure that all pairs of memory modules

in size, speed, and

installed; faulty or improperly seated

are of the same type and size and that

technology. The following

memory module(s).

they are properly installed. See "System

DIMM pair is mismatched:

 

Memory" on page 89. If the problem

DIMM x and DIMM y.

 

persists, see "Troubleshooting System

 

 

Memory" on page 120.

28