Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E2111

SBE Log Disable

The system BIOS has disabled

See "Troubleshooting System

 

Crd # DIMM ##

memory single-bit error (SBE)

Memory" on page 120.

 

 

logging, and will not resume

 

 

 

logging further SBEs until the

 

 

 

system is rebooted. "##"

 

 

 

represents the DIMM implicated

 

 

 

by the BIOS. If no memory riser

 

 

 

card is present, the "Crd #" string

 

 

 

is left out of the message.

 

 

 

 

 

E2112

Mem Spare Crd #

The system BIOS has spared the

See "Troubleshooting System

 

DIMM ##

memory because it has

Memory" on page 120.

 

 

determined that the memory had

 

 

 

too many errors. "## & ##"

 

 

 

represents the DIMM pair

 

 

 

implicated by the BIOS. If no

 

 

 

memory card is present, the "Crd

 

 

 

#" string is left out of the

 

 

 

message.

 

 

 

 

 

E2113

Mem Mirror Crd #

The system BIOS has disabled

See "Troubleshooting System

 

DIMM ## & ##

memory mirroring because it has

Memory" on page 120.

 

 

determined that one half of the

 

 

 

mirror has had too many errors.

 

 

 

"## & ##" represents the

 

 

 

DIMM pair implicated by the

 

 

 

BIOS. If no memory card is

 

 

 

present, the "Crd #" string is left

 

 

 

out of the message.

 

 

 

 

 

E2118

Fatal NB Mem CRC

One of the connections in the

See "Troubleshooting System

 

 

Fully Buffered DIMM (FBD)

Memory" on page 120.

 

 

memory subsystem link on the

 

 

 

Northbound side has failed.

 

 

 

 

 

E2119

Fatal SB Mem CRC

One of the connections in the

See "Troubleshooting System

 

 

FBD memory subsystem link on

Memory" on page 120.

 

 

the Southbound side has failed.

 

 

 

 

 

I1910

Intrusion

System cover has been removed.

Information only.

 

 

 

 

I1911

>3 ERRs Chk Log

LCD overflow message.

Check the SEL for details on the

 

 

A maximum of three error

events.

 

 

 

messages can display sequentially on the LCD. The fourth message displays as the standard overflow message.