Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

DIMMs must be populated in sequential order beginning with slot 1. The following DIMM is electrically isolated: DIMM x.

The specified DIMM is inaccessible to

Populate 2, 4, or 8 DIMMs sequentially

the system due to its location. DIMMs

beginning with slot 1. See "System

must be populated in sequential order,

Memory" on page 89.

beginning with slot 1.

 

DIMMs should be installed in pairs. Pairs must be matched in size, speed, and technology.

Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). The system will operate in a degraded mode with reduced ECC protection. Only memory installed in channel 0 will be accessible.

Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "System Memory" on page 89. If the problem persists, see "Troubleshooting System Memory" on page 120.

Dual-rank DIMM paired with Single-rank DIMM - The following DIMM/rank has been disabled by BIOS: DIMM x Rank y

Mismatched DIMMs installed; faulty memory module(s). The system has detected a dual-rank DIMM paired with a single-rank DIMM. The second rank of the dual-rank DIMM will be disabled.

Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "System Memory" on page 89. If the problem persists, see "Troubleshooting System Memory" on page 120.

Diskette drive n seek

Incorrect configuration settings in the

failure

System Setup program.

 

Faulty or improperly installed diskette

 

drive.

 

Loose tape drive interface cable, or

 

loose power cable.

Run the System Setup program to correct the settings. See "Using the System Setup Program" on page 37.

Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 121.

Reseat tape drive interface cable, or power cable. If the problem persists, see "Troubleshooting a Diskette Drive" on page 121.

Diskette read failure

Faulty or improperly inserted diskette

 

or tape drive.

Replace the diskette. See "Troubleshooting a Diskette Drive" on page 121.

Diskette subsystem reset

Faulty or improperly installed diskette

failed

or tape drive.

Replace the diskette or tape. If the problem persists, see "Troubleshooting a Diskette Drive" on page 121.

Drive not ready

Diskette missing from or improperly

 

inserted in diskette drive.

Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 121.

About Your System

29

Page 29
Image 29
Dell 2950 owner manual Diskette drive n seek, Failure, Diskette read failure, Diskette subsystem reset, Drive not ready