Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1811

HDD ## Rbld Abrt

The specified hard drive has

See "Troubleshooting a Hard

 

 

experienced a rebuild abort.

Drive" on page 124. If the

 

 

 

problem persists, see your RAID

 

 

 

documentation.

 

 

 

 

E1812

HDD ## Removed

The specified hard drive has been

Information only.

 

 

removed from the system.

 

 

 

 

 

E1913

CPU & Firmware

The BMC firmware does not

Update to the latest BMC

 

Mismatch

support the CPU.

firmware. See the BMC User’s

 

 

 

Guide for more information on

 

 

 

setup and use of BMC.

 

 

 

 

E1A11

PCI Rsr Config

PCI risers are not configured

See "Expansion-Card Riser

 

 

correctly; some invalid

Boards" on page 98.

 

 

configurations may prevent the

 

 

 

system from powering on.

 

 

 

 

 

E1A12

PCI Rsr Missing

One or all of the PCI risers is

Information only.

 

 

missing, preventing the system

 

 

 

from powering on.

 

E1A14

SAS Cable A

SAS cable A is missing or bad.

Reseat the cable. If problem persists, replace cable. See "SAS Controller Daughter Card" on page 69.

E1A15

SAS Cable B

SAS cable B is missing or bad.

Reseat the cable. If problem persists, replace cable. See "SAS Controller Daughter Card" on page 69.

E2010

No Memory

No memory is installed in the

Install memory. See "Installing

 

 

system.

Memory Modules" on page 90.

 

 

 

 

E2011

Mem Config Err

Memory detected, but is not

See "Troubleshooting System

 

 

configurable. Error detected

Memory" on page 120.

 

 

during memory configuration.

 

 

 

 

 

E2012

Unusable Memory

Memory is configured, but not

See "Troubleshooting System

 

 

usable. Memory subsystem

Memory" on page 120.

 

 

failure.

 

 

 

 

 

E2013

Shadow BIOS Fail

The system BIOS failed to copy

See "Troubleshooting System

 

 

its flash image into memory.

Memory" on page 120.

 

 

 

 

E2014

CMOS Fail

CMOS failure. CMOS RAM not

See "Getting Help" on page 147.

 

 

functioning properly.

 

 

 

 

 

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 147.