Message

Causes

Corrective Actions

No boot device

Faulty or missing optical

available.

drive subsystem, hard drive,

 

or hard-drive subsystem, or

 

no bootable USB key

 

installed.

Use a bootable USB key, CD, or hard drive. If the problem persists, see "Troubleshooting a USB Device" on page 112, "Troubleshooting an Optical Drive" on page 121, and "Troubleshooting a Hard Drive" on page 123. See "Using the System Setup Program and UEFI Boot Manager" on page 35 for information on setting the order of boot devices.

No boot sector on Incorrect configuration

hard drive. settings in System Setup program, or no operating system on hard drive.

Check the hard-drive configuration settings in the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on page 35. If necessary, install the operating system on your hard drive. See your operating system documentation.

No timer tick

Faulty system board.

See "Getting Help" on

interrupt.

 

page 135.

 

 

 

PCI BIOS failed

PCIe device BIOS (Option

Reseat the expansion card(s).

to install.

ROM) checksum failure

Ensure that all appropriate

 

detected during shadowing.

cables are securely connected

 

Cables to expansion card(s)

to the expansion card(s). If the

 

loose; faulty or improperly

problem persists, see

 

installed expansion card(s).

"Troubleshooting Expansion

 

 

Cards" on page 124.

PCIe Training Error: Expected Link Width is x, Actual Link Width is y.

Faulty or improperly installed PCIe card in the specified slot.

Reseat the PCIe card in the specified slot number. See "Troubleshooting Expansion Cards" on page 124. If the problem persists, see "Getting Help" on page 135.