Message

Causes

Corrective Actions

The following

Invalid memory

DIMMs should

configuration. The

match in

specified memory modules

geometry:

do not match in size,

x,x,...

number of ranks, or

The following

number of data lanes.

 

DIMMs should

 

match in rank

 

Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 86.

count: x,x,...

The following DIMMs should match in size: x,x,...

The following DIMMs should match in size and geometry: x,x,...

The following DIMMs should match in size and rank count: x,x,...

Thermal sensor

A memory module without

Replace the memory module.

not detected on

a thermal sensor is installed

See "System Memory" on

x.

in the specified memory

page 86.

 

slot.

 

 

 

 

Time-of-day

Faulty battery or faulty

See "Troubleshooting the

clock stopped.

chip.

System Battery" on page 116.

 

 

 

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program.

battery.

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 35. If the problem

 

 

persists, replace the system

 

 

battery. See "System Battery"

 

 

on page 97.