System Messages

Table 1-2. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

W1228

RAID

Warns predictively that the

Allow RAID battery to

 

Controller

RAID battery has less than

charge to greater than

 

battery

24 hours of charge left.

24 hours of sustained

 

capacity

 

charge.

 

< 24hr.

 

If problem persists,

 

 

 

 

 

 

replace the RAID battery.

 

 

 

See "Installing a RAID

 

 

 

Battery" on page 133.

 

 

 

 

W1627

Power

The system configuration

Turn off power to the

 

required

requires more power than

system, reduce the

 

> PSU

what the power supply can

hardware configuration or

 

wattage.

provide.

install higher-wattage

 

Check PSU and

 

power supplies, and then

 

config.

 

restart the system.

 

 

 

 

W1628

Performance

The system configuration

Turn off power to the

 

degraded.

requires more power than

system, reduce the

 

Check PSU and

what the power supply

hardware configuration or

 

system

can provide, but it can

install higher-wattage

 

configur-

boot if throttled.

power supplies, and then

 

ation.

 

restart the system.

 

 

 

 

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.

System Messages

System messages appear on the screen to notify you of a possible problem with the system.

NOTE: If you receive a system message not listed in the table, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

About Your System

39

Page 39
Image 39
Dell T310 owner manual System Messages