Lighting The Infrared or Rotisserie Burner
1.Open the hood.
2.Push in and turn counter clockwise the gas control knob for the IR (infrared) burner to the HI position. This is the knob farthest to the left. On units with two IR burners, the control knob for the right IR burner is the knob farthest to the right.
3.“Push Igniter Button; a multiple clicking noise should be heard from the igniter indicating a spark is being provided to the burner.
4.If the burner does not light on the first try, repeat immediately.
5.If the burner does not light within 5 seconds, turn the control knob to the OFF position. Wait 5 minutes until the gas clears before attempting to light it again.
6.Repeat the procedure or try “Manual Lighting procedure” as shown below.
7.Upon successful lighting, repeat the process on any other available IR burner you may wish to light.
Wait 5 minutes before
Manually Lighting The Infrared or
Rotisserie Burner
1.Open the hood.
2.Push in and turn counter clockwise the gas control knob for the IR (infrared) burner to the HI position.
3.Hold a lit long stem match next to the burner ports.
4.If the burner does not light within 5 seconds, turn the control knob to the OFF position. Wait 5 minutes until the gas clears before attempting to light it again.
5.If the burner does not light after several attempts see troubleshooting guide on page 37.
6.Upon successful lighting, repeat the process on any other available IR burner you may wish to light.
Wait 5 minutes before
operation
BURNER CONTROL KNOB
IGNITER BUTTON
23
Operation