protocol.

Here are the descriptions of every setup item:

Item

Description

Enable RS-485

Check this box to enable RS-485 functionality.

Use Pelco-D

Select this option and RS-485 interface will output pan-tile control signal

 

in Pelco-D format. This format is widely accepted by most of pan-tilt

 

camera cradles.

 

You have also input pan-tilt camera cradle’s address code in ‘Address’

 

field (number must be between 0~255). This code must be identical to

 

pan-tilt camera cradle’s address code.

Use Custom

When the pan-tilt camera cradle does not support Pelco-D protocol, you

Protocol

can define a protocol’s detail by this function.

 

Please refer to pan-tilt camera cradle’s user manual to define the

 

protocol.

 

- Baud Rate: Select data baud rate of RS-485 interface that pan-tilt

 

camera cradle will accept. When the length of RS-485 connection is

 

very long (longer than 200M), it’s not recommended to use high

 

speed connection (greater than 2400bps).

 

- Data Bits: Select data bits of RS-485 connection.

 

- Parity: Select parity bit: odd, even, or space.

 