Appendix C: Command Line Reference | X.25 209 |
|
|
X.25
SET X25 ADDRESS localX25addr
Valid context: Profile
Sets the X.25 DTE address assigned to the DIVA LAN ISDN Modem. Specify up to 15 digits.
localX25addr: DTE address of the device.
SET X25 CUD callUserData
Valid context: Profile
Specifies the call user data the device will include when establishing an X.25 call.
callUserData: Call user data as hexidecimal digits separated by commas, colons, or hyphens. Maximum length
is 16 bytes. For example: 42,07,07
SET X25 FACILITIES hexstring
Valid context: Profile
Sets the X.25 facilities used to establish an X.25 call with this profile.
hexstring: Encode facilities as a hexadecimal string of characters separated by commas, colons, or hyphens.
Maximum length is 14 bytes. For example: 42,07,07
SET X25 LCN lcnNumber
Valid context:
Sets the lowest X.25 logical channel number (LCN) available.
LCNnumber: Logical channel number.
SET X25 MAXIDLETIME seconds
Valid context: Profile
Sets the maximum amount of time an X.25 connection can be idle before the DIVA LAN ISDN Modem drops the connection.
maxIdleTime: Maximum time a connection can be idle. Range: 0 (never
disconnect), 1 to 600 seconds. Default: 20 seconds.
SET X25 MINCONTIME seconds
Valid context: Profile
Sets the minimum amount of time an X.25 connection must stay connected.
minConnectionTime: Minimum time an X.25 connection must stay connected. Range: 0 to 1800 seconds.
Default: 30 seconds.
SET X25 NUMSVC svc
Valid context: General
Sets the number of X.25 SVCs (switched virtual circuits) supported for X.25 communications over the