46
Signals connector - J3 - cont.
| Pin | Function | Remarks |
|
|
|
|
|
|
|
|
| 18 | Inhibit output | Relay contact (potential free). |
|
|
|
|
| The relay contact is closed whenever the |
|
|
|
|
| amplifier is enabled. Contact rating: 0.5A, 200V, |
|
|
|
|
| 10W. |
|
|
| 19 | Motion command (+5V) | This analog output represents the current command |
|
|
|
|
| from the position loop to the power amplifier. It |
|
|
|
|
| is useful for monitoring the position loop |
|
|
|
|
| response. |
|
|
| 20 | Circuit common |
|
|
|
| 21 | Reset input | * |
|
|
| 22 | Circuit common |
|
|
|
| 23 | Tachogenerator | When using the resolver option this output is the |
|
|
|
| output/input | velocity monitor with a scale of 8V for maximum |
|
|
|
|
| speed. See 7.3. |
|
|
| 24 | Circuit common |
|
|
|
| 25 | Velocity / current mode | When input is left open (low level) the analog |
|
|
|
| selection | part of the amplifier is working in current mode. |
|
|
|
|
| when a high level signal is applied (>2V), the |
|
|
|
|
| analog part of the amplifier is working as a high |
|
|
|
|
| gain velocity amplifier. * |
|
|
| 26 | Not connected |
|
|
|
|
|
|
|
|
|
Signals connector - J4 |
|
| |||
|
|
|
|
|
|
| Pin | Function | Remarks |
|
|
1
2
3
4
5
Input 1 | * | |
Input 2 | * | |
Circuit common |
| |
Input | 3 | * |
Input | 4 | * |
* Vil<1V, Vih>2.4V, Maximum input voltage: +30VDC