| 49 |
Signals connector - J6 - cont. |
| ||
| Pin | Function | Remarks |
|
|
|
|
| 5 | Auxiliary encoder index |
|
|
| input |
|
| 6 | +5V output | There are several +5V pins. The accumulative |
|
|
| external load should not exceed 200mA. |
| 7 | +15V output | There are several +15V pins. The accumulative |
|
|
| external load should not exceed 100mA. |
| 8 | Circuit common |
|
| 9 | Home switch | * |
| 10 | +5V output | There are several +5V pins. The accumulative |
|
|
| external load should not exceed 200mA. |
| 11 | Abort input | This input must be connected to high level |
|
|
| voltage to enable the amplifier. * |
| 12 | +5V output | 200mA |
| 13 | Forward limit switch | This committed input activates the #[ subroutine. |
|
|
| * |
| 14 | Reverse limit switch | This committed input activates the #[ subroutine. |
|
|
| * |
| 15 | Circuit common |
|
|
|
|
|
J1A, FAN TERMINALS - (MBA-DBP/6U ONLY)
1024VDC common - fan only.
11+24VDC isolated supply for fan (max. 400mA)
* Vil<1V, Vih>2.4V, Maximum input voltage: +30VDC