9. Tables and Summaries
9.1 Display diagnostics
Each amplifier's fault is stored immediately in the DCB RAM. In addition to that, a Failure Message is displayed. Following are all the valid Display Messages:
Event | Display | Display |
|
| after |
|
| Recurring |
|
|
|
DIP switch 1 - ON | BAUD | OK |
Load is under cont. current limit | CLIM | |
Battery Low | BATT | |
Abort condition (hardware only) | ABRT | |
Amplifier's power stage disabled * | AMPD | |
Under or Over Voltage | VOLT | |
+15V out of limits | +15V | |
Over Temperature | TEMP | |
Commutation problem (for brushless drives | CMMT | |
only) |
|
|
Short condition at the power outputs | SHRT | |
|
|
|
*The AMPD message appears in two cases:
1.When MO (Motor Off) command is given.
2.Position error exceeds the allowed value.