9. Tables and Summaries

9.1 Display diagnostics

Each amplifier's fault is stored immediately in the DCB RAM. In addition to that, a Failure Message is displayed. Following are all the valid Display Messages:

Event

Display

Display

 

 

after

 

 

Recurring

 

 

 

DIP switch 1 - ON

BAUD

OK

Load is under cont. current limit

CLIM

C-OK

Battery Low

BATT

B-OK

Abort condition (hardware only)

ABRT

A-OK

Amplifier's power stage disabled *

AMPD

H-OK

-15V out of limits

-15V

F-OK

Under or Over Voltage

VOLT

F-OK

+15V out of limits

+15V

F-OK

Over Temperature

TEMP

F-OK

Commutation problem (for brushless drives

CMMT

F-OK

only)

 

 

Short condition at the power outputs

SHRT

F-OK

 

 

 

*The AMPD message appears in two cases:

1.When MO (Motor Off) command is given.

2.Position error exceeds the allowed value.